configuration which was developed by the low carbon steel series of tests because the steel was easy to machine and modify. The HIPERCO magnet was designed, using the analyses codes which were verified by the carbon steel magnet tests, to be prototypic of the GFS pump. The magnet’s analytically predicted performance was experimentally verified and this design will be directly incorporated into the Electro Magnetic Integration Test (EMIT) which is scheduled to be complete in FY 1990. The magnetic bench test results from the HIPERCO magnets verified the magnetic performance analyses codes. The GFS pump magnetic structure design was changed as